banner
Products
The synergy between our production line and R&D team ensures timely and efficient outcomes.
Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t Sr-B3-23A Sr-B3-52A Srb3-95A Heat Exchanger

Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t Sr-B3-23A Sr-B3-52A Srb3-95A Heat Exchanger

Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t SR-B3-23A SR-B3-52A SRB3-;
Basic Info
Model NO. F80 F85 F120T P120T
Max Pressure 3/4.5 MPa
Test Pressure 4.5/6.7 MPa
Max Temperature 225c
Type Stainless Steel Heating Equipment
Ceramic Heating Equipment Type Stainless Steel Heater
Recuperative Heat Exchanger Type Plate Heat Exchanger
Transport Package Standard Plywood Box
Specification ISO9001, CE, UL, WRAS, ROHS and etc.
Trademark Baode
Origin China
HS Code 8419500090
Production Capacity 1000 PCS/Month
Product Description
Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t SR-B3-23A SR-B3-52A SRB3-95A heat exchanger
Evaporator flow principle
The channels formed between the corrugated plates and corners are arranged so that the two media flow
through alternate channels, always in opposite directions (counter current flow). The two phase refrigerant
(vapor + liquid) enters the bottom left of the exchanger with a vapor quality depending on the operating
condition of the plant. Evaporation of the liquid phase takes place inside the channels and some degrees of
superheat are always requested, which is the reason why the process is called "dry expansion". In the enclosed
evaporator picture the dark and light blue arrows show the location of the refrigerant connections. The water
(brine) to be cooled flows counter current in the opposite channel; the dark and light red arrows show the
location of the water (brine) connections.

Standard design
The plate pack is covered by cover plates. Connections are located in the front or rear cover plate. The channel
plates are corrugated to improve heat transfer efficiency and to make them rigid.

Dual system
The real dual circuit patented by Baode in a solution with diagonal flow is obtained by means of pressed plates. The Brazed Plate Heat Exchanger can be connected with two independent refrigerant circuits. The special design ensures that each refrigerant circuit is in contact with the entire water flow. The main advantage is that at partial load (only one compressor running) water cooling is uniform and performance is maximized.

Standard materials
Cover plates: Stainless steel AISI 316
Connections: Stainless steel AISI 316
Plates: Stainless steel AISI 316
Brazing material: Copper

Particulars required for quotation
To enable Baode's representative to make a specific quotation, enquiries should be accompanied by the following
particulars:
- flow rates or heat load required
- temperature program
- physical properties of liquids in question
- desired working pressure
- maximum permitted pressure drop

Short delivery time.
High quality
Reasonable price
Customer made
Know-how design and customer support

Certified by ISO9001, CE, WRAS, UL, RoHS, CCS etc. A.

Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t Sr-B3-23A Sr-B3-52A Srb3-95A Heat Exchanger

Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t Sr-B3-23A Sr-B3-52A Srb3-95A Heat Exchanger

Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t Sr-B3-23A Sr-B3-52A Srb3-95A Heat Exchanger

Evaporator Brazed Plate Heat Exchanger 25kw 75kw 225kw Swep Heat Exchanger F80 F120t F85 S500t Sr-B3-23A Sr-B3-52A Srb3-95A Heat Exchanger

 

Send inquiry